SPECIFICATION
SHEET AQUATEST 2010 |
Aquatest 2010 The standard diaphram type generator is recommended when the vaporizer is used, when the total amount of water measured is very small (less than 100 ug), or where the more aggressive solvent action of the pyridine or pyridene free reagents is needed. |
|
INDUSTRY
|
APPLICATIONS:
|
SPECIFICATIONS
Method: | Microporcessor Controlled Karl Fischer Coulometric Titrimetry |
Detection: | Constant Current Polarization Detection |
Titration Control: | Automatic Electrolysis Current Control |
Titration Rate: | Max. 2400 µg H2O/min., microprocessor controlled |
Background Compensation: | Automatic Correction, Full-time Display (µg H2O/sec) |
Measuring Range: | 10 µg to 100 mg H2O |
Sensitivity: | 0.1 µg H2O |
Precision: | ± 3 µg for 10 µg to 1 mg H2O, C.V. = 0.3% or less for 5000 µg H2O |
Display: | Large 20 Character LCD |
Files: | 8 Titration Files, 99 Sample Data Points |
Calculation: | Concentration (µg, %, ppm, mg/L), Mean, Standard Deviation, Coefficient of Variation |
Printer: | 21-digit Thermal Dot Matrix Printer, Paper Width 57 mm |
Input/Output: | Standard Built-in
RS-232C Dedicated Balance Interface, Ohaus Adventurer and
Analytical Plus balances are available from Photovolt
with everything you need to interface with the 2010. Call
or email for specially reduced package price when
purchased with the 2010. Standard Build-in RS-232C Computer Interface |
Auxiliary Functions: | Self-Diagnostics, Reagent Consumption Indicator, Data Recalculation, Power off Memory-2-month Operation after Full Charge, GLP formatted Data Output |
Sample Introduction: | Vertical and Angled Sample Ports. Indirect: Optional Vaporizer |
Power Requirement: | AC 100V, 115V, 220V, 240V, 50/60Hz, 160VA |
Dimensions: | Approx. 450 mm (W)
x 335 mm (D) x 140 (H) 17.75" (W) x 13.25" (D) x 5.5" (H) |
Weight (Packed): | Approx, 8.6 kg (18.75 lbs.) |
AQUATEST 2010 VAPORIZER SPECIFICATIONS
Temperature Range: | 50°C to 300°C (at an ambient temperature of 25°C) |
Oven Type: | Transparent Electro-Conductive Glass, 120 VA |
Sample Capacity: | Up to 10 grams (depends upon sample matrix) |
Measurable Range: | From 5 ppm |
Gas Requirements: | 100 to 500 mL/min Nitrogen Supplied at 2 kg/cm²g (30 psi) |
Sample Introduction: | Automatic Sample Boat Loader |
Moisture Transfer: | Via Heated Gas Transfer Line (105°C) |
Blank Reduction: | Via Automatic Moisture Purge System |
Dimensions: | Approx. 508 mm
(W) x 203 mm (D) x 178 mm (H) 20" (W) x 8" (D) x 7" (H) |
Weight (Packed): | Approx. 6.1 kg (13.25 lbs) |
Giangarlo
Scientific | Analytical | Environmental | Life Science | Process | Safety | Wastewater | Service | Contact Us